KinTek AutoSF-120 Stopped-Flow


The AutoSF-120 enables the new exciting era of automated high throughput stopped flow!

Request a quote


KinTek has always been a leader in building stopped-flow instruments that conserve precious samples. The all new AutoSF-120 sets a new standard for sample economy, requiring only 120 microliters of sample to flush, load and collect data, while giving with 3-4 replicate measurements. The flushing and sample loading are all done automatically. Simply pipette 120 microliters of solution into each sample cup and click "Load".

In the process of designing this new state-of-the-art instrument, we also added new noise reduction electronic circuits to improve signal:noise twofold and achieved a submillisecond dead time. In addition we completely re-wrote the system software for data collection and analysis to give unparalleled ease of use and power.

The KinTek AutoSF is by far the best stopped-flow instrument ever built, giving you more high quality data while consuming less sample and less time.

An optional robotic autosampler increases throughput even more to afford unattended stopped-flow measurements of hundreds of samples per day.

Features

  • Small sample volume: 120 µL is sufficient to flush and load a new sample and get 3-4 reproducible shots. All other instruments require 3-5 times as much sample.
  • Automated computer-controlled load/flush/fire cycle — simply pipet 120 µL into each sample cup and click "load".
  • Twofold improvement in signal/noise with new noise reduction circuits
  • Compact footprint: instrument and electronics combined (14 × 26.5 × 4.5 inches)
  • Computer optimized optical path with lower noise and background fluorescence

Optional Robot Affords High Throughput Screening

The AutoSF-120 can be optionally supplied with a robot that automates loading of up to 96 pairs of samples. Stopped-flow data are collected and the results are tabulated for easy review. This unique functionality allows unattended high-throughput screening while still delivering the rich zinformation content derived from transient-state kinetic analyses.

Automatic Sample Loading

Even without the robot, the KinTek AutoSF-120 affords automatic sample loading and syringe flushing between samples while consuming the minimal volume of sample. The AutoSF-120 requires 3- to 5-fold less sample compared to other stopped-flow instruments!

An optical fiber from the light source plugs into the Optical Fiber holder. There are two sliders which hold filters for each PMT (photomultiplier tube). Pull out the slider and insert the appropriate 25.4 mm diameter filter. Attached a syringe to the EXlT line to collect waste solution.





Sample Load Ports:

There are three different sample load ports (listed below) that can be installed. The photo at the right shows sample load ports with the Syringe Adapters installed. To change sample load ports, use the spanner wrench provided to unscrew the load port and replace it with the new one.













Sample Load Port Options:

Syringe adapters allow a syringe (without a leur lock) to be inserted into the port. Remove the plunger from the syringe before attaching it to the AutoSF so that you can then pipette sample into the syringe so that you sample can be automatically drawn into the instrument.

Micro volume adapters contain a conical sample holder into which small volumes (up to 350 µL) can be pipetted, either manually or robotically.

Tubing adapters allow solution to be fed into the instrument through a 1/16" diameter tubing.

Syringe Flush/Load Control

missing image here

KinTek stopped-flow system software allows the user to Load Samples and Flush Syringes and to control the volumes taken up during each action.

Text entries under Syringe Volume Controls define the volumes for loading and flushing each syringe. Start by entering a value of 300 next to the Flush Syringes button, then pipette at least 300 µL of buffer into each load port, and then press Flush Syringes. The instrument will automatically load and expel the set volume. Repeat as needed. To load the syringes with 100 µL of solution, pipette 120 µL into each load port, then press "Load Sample" as described below. Recommended minimal load volume is 120 µL, while the recommended flush volume is 300 µL.







Summary

The KinTek AutoSF-120 represents a significant advancement in the universe of transient-state kinetics.

Contact our sales office to get more information on this exciting new advance in stopped-flow instrumentation. The AutoSF stands out in a class by itself. No other instrument offers such sample economy, ease of use and power to collect the most precise data to answer important scientific questions.

The KinTek SF software also allows for easy export of data for analysis using KinTek Global Kinetic Explorer, the most advance and powerful data fitting package available, allowing you to fit data to models based upon experimental designs, not to equations.